Cooling of industrial and office buildings

Comfort Cooling

A large number of options are available for comfort cooling, with air conditioning and refrigeration systems being classified as centralised or decentralised systems, depending on their mode of operation and installation.

  • Air cooling systems
  • Air to water systems
  • Water-only systems (chilled beam or ceiling applications etc.)

The eChiller is suited for air-water systems, and particularly to water-only systems. Water-only systems include chilled beams and ceilings, as well as all other types of convectors.

BlueZero Building – Building air conditioning with the refrigerant water

Find out more about the ecological concept of climatisation of buildings from Ef cient Energy

Go to BlueZero Building

 

Surface cooling systems

Chilled beams and ceilings are used in comfort cooling for rejecting huge heat loads to ambient.
Surface cooling systems use a network of pipes through which water is pumped (typically at 16° C) to absorb heat, cooling the room. Metal-panel and cassette ceilings with pressed coils and thermal insulation are used for closed ceiling surface cooling applications with heat transfer capabilities in the range of 80 W/m² to 100 W/m². Open ceiling surface cooling applications, in the contrary, which include cooling plates and cooling sails, have transfer capabilities in the range of 100 W/m² to 130 W/m².

Building component activation

The use of cooling or heating systems that use a building’s mass for temperature control is also known as “building component activation” or “concrete core activation”. Building component activation uses a meandering system of pipes laid in the concrete floor/ceiling slabs, and water as the cooling medium. The thermal loads which accumulate during the day are stored in the concrete, and transferred to the cooling water during night-time. Concrete core activation is ideal for water pump-based cooling.

Chilled water cassettes

Chilled water cassettes offer an optimal solution for all small and large rooms in which the installation of free convection is not feasible. Chilled water cassettes are usually installed in the suspended ceiling and come with a range of cooling capacities. These can be operated with a chilled water temperature of 16° C, too.
The central challenges for operators of comfort cooling are:

  • Guideline compliance, certifications (EnEff, DGNB, LEED)
  • F-Gas-Regulation
  • Predicting behaviour under partial load in new buildings; determining the maximum required load
  • Choice of system

The eChiller offers the following benefits for comfort cooling

  • Highly efficient thanks to fully adjustable, integrated free cooling
  • The F-Gas-Regulation and DIN EN 378 do not apply
  • Very quiet and vibration-free
  • Cooling capacity easily scaled thanks to integrated cluster control
  • Free choice of installation location
  • Machine room for installation is not required

Comfort cooling that grows with your building’s needs

Given the eChiller’s emission-free design, an installation close to the cooling loads is recommended when planning the building. This avoids extensive piping and thus pressure- and energy losses, as well as availability risks. At the same time, this semi-centralised installation greatly simplifies the apportioning of energy costs within large buildings. In this way, varying cooling requirements can be easily accommodated – and often centrally controlled – across different zones of a single storey.

Example of a comfort cooling installation